近年來隨著國際間多起捷運與地下鐵系統之火災事故,造成極大的人員傷亡,歸納其事件造成重大傷亡之主要原因在於煙控系統之操作失效或緊急運轉策略不健全。因此,本文由美國國家標準局研發之火災成長預測方程式—FDS(Fire Dynamics Simulator)與另一國際間流體計算應用著名軟體(Star-CD),模擬比較地下車站火災時狀況且預測火災之煙沈積高度,和高度沈降速率。模擬結果顯示煙沈積高度及煙沈積速度比對之誤差皆在工程容許範圍內,對往後CFD模擬有著重要參考價值。

Abstract
In recent year, there were many fire accidents in MRT and subway station,due to faolure in smoke control system and emergency operation strategies. The goal of this project is to use two sofeware—FDS and Star-CD to simulate the fire in MRT station and predict the height of smoke layer and its descending rate .The comparison of the two indicated sucessful result can be obtained with deviations within engineering tolerance..
目次 Table of Contents
第一章 緒論
1-1研究背景與目的
1-2研究方法
1-3文獻回顧
1-3-1性能式煙控系統
1-3-2選擇煙捲吸率預測公式與N值決定
1-4研究步驟與內容

第二章 數值方法
2-1(LES)大尺度渦流模擬方法
2-1-1火災模擬程式FDS說明
2-2(RANS)雷諾時間平均法
2-3格點測試

第三章 環境說明與設定
3-1火源設計說明
3-2 火源熱釋放率之決定
3-3 模擬結果判斷標準

第四章 FDS與Star-CD模擬結果
4-1模型參數與邊界條件說明
4-2模擬結果說明

第五章 結論
(1)車站模擬結果分析
(1)FDS與Star-CD軟體功能比較
參考文獻 References
[1] B.McCaffrey , ” Flame Height “ , The SFPE Handbook of Fire Protection Engineering , Section 2: Fire Dynamics , 1995.
[2] Chow W. K., W. K. Wong, “On the Simulation of Atrium Fire Environment in Hong Kong Using Zone Models”, Journal of Fire Science, Vol. 11, 1993, pp. 3~51
[3] Chow, W. K., Lo, Anthony C. W., “Scale Modelling Studies on Atrium Smoke Movement and the Smoke Filling Process”, Journal of Fire Prot. Engr. Vol. 7, No. 2, 1995, pp. 55~64.
[4] E.G. Butcher , A.C. Parnell , “ Smoke Control in Fire Safety Design ” , London , E. & F. N. Spon , 1979.
[5] Fruin, J.J., Pedestrian Planning and Design, Metropoltan Association of Urban Designers and Environmental Planners, Inc., New York, 1971.
[6] K. H. Yang, J. N. Lee, “Analysis of Performance-based Smoke Management System Design in a Shopping Mall”, International Journal on Architectural Science, Vol. , 2001.
[7]. NFPA, 2000 “NFPA 92B Guide for Smoke Management Systems in Malls, Atria, and Large Areas”, National Fire Protection Association.
[8] Chow W. K., W. K. Wong, “On the Simulation of Atrium Fire Environment in Hong Kong Using Zone Models”, Journal of Fire Science, Vol. 11, 1993, pp. 3~51.
[9]. Chow, W. K. et al, Experimental Studies on Natural Smoke Filling in Atria, Journal of Fire Science, Vol. 18, 2000, pp. 84-103.
[10]. Chow, W. K., Lo, Anthony C. W., “Scale Modelling Studies on Atrium Smoke Movement and the Smoke Filling Process”, Journal of Fire Prot. Engr. Vol. 7, No. 2, 1995, pp. 55~64.
[11]. Chow, W. K., Y. Z. Li, E. Cui, R. Huo, “Natural Smoke Filling in Atrium with liquid pool fires up to 1.6MW”, Building and Environment, Vol. 36, Issue 1, 2001, pp. 121-127.
[12]. 楊冠雄,「建築物防火之煙控設計分析」,高雄復文,民國85年。
[13] .陳弘毅,”火災學”,1998.
[14] 內政部,”各類場所消防安全設備設置標準”,1996.

電子全文 Fulltext
本電子全文僅授權使用者為學術研究之目的,進行個人非營利性質之檢索、閱讀、列印。請遵守中華民國著作權法之相關規定,切勿任意重製、散佈、改作、轉貼、播送,以免觸法。
論文使用權限 Thesis access permission:校內校外完全公開 unrestricted
開放時間 Available:
校內 Campus: 已公開 available
校外 Off-campus: 已公開 available


紙本論文 Printed copies
紙本論文的公開資訊在102學年度以後相對較為完整。如果需要查詢101學年度以前的紙本論文公開資訊,請聯繫圖資處紙本論文服務櫃台。如有不便之處敬請見諒。
開放時間 available 已公開 available

QR Code