論文名稱 Title |
溫控融合微滴電噴灑游離質譜法的開發以及其應用在生化分子的分析 Development of Temperature-Controlled Fused-Droplet Electrospray Ionization MassSpectrometry and Its Application in the Analysis of Biomolecular |
||
系所名稱 Department |
|||
畢業學年期 Year, semester |
語文別 Language |
||
學位類別 Degree |
頁數 Number of pages |
69 |
|
研究生 Author |
|||
指導教授 Advisor |
|||
召集委員 Convenor |
|||
口試委員 Advisory Committee |
|||
口試日期 Date of Exam |
2003-06-13 |
繳交日期 Date of Submission |
2003-06-23 |
關鍵字 Keywords |
融合微滴電噴灑游離質譜法、蛋白質、有機分子、電噴灑游離法、聚合物、大氣壓力化學游離法 ESI, Polymer, APCI, FD-ESI/MS, Organic compound, Protein |
||
統計 Statistics |
本論文已被瀏覽 5689 次,被下載 3448 次 The thesis/dissertation has been browsed 5689 times, has been downloaded 3448 times. |
中文摘要 |
本研究即是針對解決分析不同物種需採用不同的游離法才能得到訊號,而目前液相層析質譜法(LC/MS)中最主要的兩種游離方法分別是大氣壓力化學游離(APCI)和電噴灑游離(ESI)法,由於這兩種游離法的游離機制並不同,因此游離源的裝置也不同。當分析不同物種時就須要更換游離源,非常耗時、費工,因而發展一套溫控融合微滴電噴灑游離質譜法(Temperature-Controlled Fused-Droplet Electrospray Ionization Mass Spectrometry),以方便不同化學物種的偵測。 研究中將廣泛使用在氣相層析法中的Temperature programming技術與本實驗室近年所開發的一項游離裝置『融合微滴電噴灑質譜法(FD-ESI)』結合,使FD-ESI 不但具有游離分析物的功能也同時具有溫度程序的功能。Temperature programming主要是在控制樣品霧化裝置的溫度,而樣品霧化裝置的溫度變化是由室溫開始逐漸增加到500℃;實驗中亦觀察到隨著溫度的增加,由霧化裝置所噴出的中性樣品液滴粒徑大小會逐漸減小,這些具不同粒徑大小的樣品液滴會和帶電荷的電噴灑液滴互相碰撞、融合產生不同的FD-ESI質譜訊號。本實驗將針對不同的分析物物種,例如蛋白質、胜肽、高分子聚合物以及有機小分子等標準樣品做一系列探討。 實驗結果發現經由霧化器所噴出的中性樣品液滴在進行溫控融合微滴電噴灑游離(FD-ESI)時,當霧化器控制在較低溫的情況下,所得到的質譜圖可以明顯觀察到是以多價電荷分子離子峰為主的質譜訊號;當霧化器加熱後,則觀察到質譜圖逐漸轉變成以具單一價電荷之分子離子峰為主的質譜訊號。推論當霧化器不加熱時所得到的是具多價電荷之分子離子峰的訊號顯然是來自ESI的游離機制。反之,利用霧化器加熱後所得的單一價電荷分子離子峰的訊號,則可能是來自APCI游離過程,因為在高溫時分析物的液滴體積是會隨著溶劑的揮發而大幅減小,而由電噴灑溶液所產生的帶電荷液滴也會受到霧化器所吹送出來之熱氮氣流的溫度影響而快速揮發,因此分析物的氣相分子則會傾向與電噴灑所形成的帶電液滴進行碰撞(經由離子-分子反應,IMR),因此高溫時FD-ESI的游離過程是以APCI游離機制為主。相反的,霧化器的溫度控制在室溫下,則分析物的液滴及電噴灑所產生的帶電液滴受到霧化器溫度的影響較小,所以溶劑揮發的程度較小,因此在室溫時則是以ESI游離機制為主。 |
Abstract |
none |
目次 Table of Contents |
論文摘要………………………………………………………………..i 目錄……………………………………………………………………iii 圖目錄……………………………………………………….………….v 壹、緒論………………………………………………………………..1 一、前言…………………………………………………………..1 二、電噴灑游離質譜法的發展歷史……………………………..4 三、電噴灑游離質譜法的原理與離子形成機制………………..7 四、融合微滴電噴灑游離質譜法的發展歷史、原理…….…...11 1.融合微滴電噴灑游離質譜法的發展歷史………………...11 2.融合微滴電噴灑游離質譜法之原理……………………...14 五、論文目標……………………………………………………16 貳、實驗………………………………………………………………17 一、儀器裝置……………………………………………………17 二、溫控融合微滴電噴灑游離質譜法之游離源組裝與實驗操作 步驟…………………………………………………………20 三、試劑及藥品的配置…………………………………………24 參、結果與討論………………………………………………………26 一、溫控融合微滴電噴灑質譜法於有機分子之分析…………26 二、溫控融合微滴電噴灑質譜法於蛋白質分子之分析………38 三、溫控融合微滴電噴灑質譜法於高分子聚合物之分析……42 四、溫控融合微滴電噴灑質譜法於混合溶液之分析…………49 五、以超音波霧化器結合氣動式霧化器於高分子聚合物之分析. ………………………………………………………………58 肆、結論………………………………………………………………64 伍、參考文獻…………………………………………………………65 圖目錄 圖一、以加熱式的氣動式霧化器作為微滴產生器的溫控融合微滴電噴灑游離源的裝置圖…………………………………………21 圖二、以超音波霧化器作為微滴產生器的溫控融合微滴電噴灑游離源的裝置圖……………………………………………………23 圖三、hemin chloride 利用可控溫式器動式霧化器於不同溫度(a)25℃(b)100℃(c)200℃之下所得的FD-ESI質譜圖……………27 圖四、hemin chloride 利用可控溫式器動式霧化器於不同溫度(a)300℃(b)350℃(c)400℃之下所得的FD-ESI質譜圖……………28 圖五、hemin chloride 利用可控溫式器動式霧化器於不同溫度(a)425℃(b)450℃(c)500℃之下所得的FD-ESI質譜圖……………29 圖六、cetylpyridinium chloride 利用可控溫式器動式霧化器於不同溫度(a)25℃(b)100℃(c)150℃(d)175℃(e)250℃之下所得的FD- ESI質譜圖…………………………………………………….33 圖七、cetylpyridinium chloride 利用可控溫式器動式霧化器於不同溫度(a)250℃(b)300℃(c)350℃(d)375℃之下所得的FD- ESI質 譜圖……………………………………………………………34 圖八、cetylpyridinium chloride 利用可控溫式器動式霧化器於不同溫度(a)400℃(b)475℃(c)500℃之下所得的FD- ESI質譜圖….35 圖九、cytochrome c 利用可控溫式器動式霧化器於不同溫度(a)25℃(b)100℃(c)150℃(d)200℃之下所得的FD- ESI質譜圖……39 圖十、cytochrome c 利用可控溫式器動式霧化器於不同溫度(a)225℃(b)250℃(c)275℃(d)300℃之下所得的FD- ESI質譜圖…40 圖十一、PEG1500 利用可控溫式器動式霧化器於不同溫度(a)25℃(b)100℃(c)125℃之下所得的FD- ESI質譜圖………………43 圖十二、PEG1500 利用可控溫式器動式霧化器於不同溫度(a)150℃(b)200℃(c)250℃之下所得的FD- ESI質譜圖………………44 圖十三、PEG1500 利用可控溫式器動式霧化器於不同溫度(a)300℃(b)350℃(c)400℃之下所得的FD- ESI質譜圖………………45 圖十四、PEG1500 利用可控溫式器動式霧化器於不同溫度(a)450℃(b)475℃(c)500℃之下所得的FD- ESI質譜圖………………46 圖十五、 protein(cytochrome c,insulin):peptide(bradykinin): polymer (PEG1000)的傳統電噴灑質譜圖………………………...49 圖十六 控制霧化氣溫度在(a)31℃(b)200℃時protein(cytochrome c, insulin):peptide(bradykinin):polymer (PEG1000)的FD-ESI質譜圖………………………………………………………50 圖十七 控制霧化氣溫度在(a)250℃(b)275℃時protein(cytochrome c, insulin):peptide(bradykinin):polymer (PEG1000)的FD-ESI質譜圖………………………………………………………51 圖十八 控制霧化氣溫度在(a)300℃(b)325℃時protein(cytochrome c, insulin):peptide(bradykinin):polymer (PEG1000)的FD-ESI質譜圖………………………………………………………52 圖十九 控制霧化氣溫度在(a)350℃(b)400℃時protein(cytochrome c, insulin):peptide(bradykinin):polymer (PEG1000)的FD-ESI質譜圖………………………………………………………53 圖二十 將圖十九的FD-ESI質譜圖進行放大………………………54 圖二十一 以超音波霧化器和氣動式霧化器作為融合微滴電噴灑游離法的微滴產生器之儀器裝置圖……………………………………59 圖二十二 利用在室溫下的氣動式霧化器與超音波霧化器於各種不同溫度下結合所得PEG1000的FD-ESI質譜圖………60 圖二十三 利用在室溫下的氣動式霧化器與超音波霧化器於各種不同溫度下結合所得PEG1000的FD-ESI質譜圖………61 圖二十四 由含二霧化液滴傳輸管的FD-ESI游離源………………63 |
參考文獻 References |
1. Thomson, J. J. “Rays of Positive Electricity and Their Application to Chemical Analysis, ” 1913, Longmans. London. 2. Nier, A. O. “Electron Impact Mass Spectrometry, ”Rev Sci Instrum. 1947,18,415. 3. Munson, M. S. B.; Field, F. H. “Chemical Ionization Mass Spectrometr , ”J.Am. Chem. Soc. 1960. 88, 2621. 4. Beckey, H. D. “ Principles of Field Ionization and Field Desorption Mass Spectrometry,” 1977,Pergamon, Oxford. 5. Benninghoven, A. ; RUdenauer, F. G.;Werner, H. W. “Secondary Ion Mass Spectrometry-Basic Concepts Instrumental Aspects ApplicationsAnd Trends,”1987,Wiely,New York. 6. Cotter, R. J. “Plasma Desorption Mass Spectrometry : Coming of Age,”Anal. Chem.1988,60,781A 7. Unsold, E. ; Hillenkamp, F.; Nitsche, R. “Mass Group Spectrometry of Peptides and Protein by Matrix Assisted Ultraviolet Laser Desorption/Ionization in Methods in Enzymology,”Analysis 1990,4,115. 8. Barber, M. ; Bordoli, R. S. ; Elliott, G. J. ; Sedgwick, R. D. ; Tyler, A. N. “Fast Atom Bombardment Mass Spectrometry,”Anal. Chem.1982, 54,645A. 9. Yamashita, M.; Fenn, J. B. “Electrospray Ion Source : Another Variation on the Free-Jet Theme,”J.Phys.Chem. 1984,88,4451. 10.Karas, M. ; Hillenkamp, F. “Laser Desorption Ionization of Proteins with Molecular Mass Exceeding 10,000Daltons,”Anal.Chem. 1988, 60,299. 11.Zeleny, J. “Industry Application of Electrospray Technology,”Phys. Rev.1917,10,1. 12.Dole, M.; Mack, L. L.; Hines, R. L. “Molecular beams of macroions,” J. Chem. Phys. 1968, 49, 2240. 13.Mack, L. L.; Kralic, P.; Rheude, A.; Dole, M. “Molecular beams of macroions Ⅱ,” J. Chem. Phys. 1970, 52, 4977. 14.Wong, S. F.; Meng, C. K.; Fenn, J. B. “Multiple charging in electrospray ionization for poly(ethylene glycols),” J. Chem. Phys. 1988, 92, 546. 15.Fenn, J. B.; Mann, M.; Meng, C. K.; Wong, S. F.; Whitehouse, G. M. “Electrospray ionization for mass spectrometry of large biomolecules,” Science. 1989, 246, 64. 16.AlekSendriv, M. L.; Gall, L. N.; Shkurov, V. A.; Pavlenko, V. A.; Krasnov, N. V.; Nikolaev, V. I. “Mechanism of ion formation during the electrohydrodynamic sputtering of a liquid into a vacuum,” J. Anal. USSR. 1984, 39, 1268. 17.Bruins, A. P.; Covey, T. R.; Henion, J. D. “Ion-spray interface for combind liquid chromatography / atomospheric pressure ionization mass spectrometry,” Anal. Chem. 1987, 59, 2642. 18.Olivares, J. A.; Nguyen, N. T.; Yonker, C. R.; Smith, R. D. “On-Line mass spectrometric detection for capillary zone electrophoresis,” Anal. Chem. 1987, 59, 1232. 19.Wahl, J. A.; Goodlett, D. R.; Useth, H. R.; Smith, R. D. “Attomole level capillary electrophoresis mass spectrometric protein analysis using 5-μm-i. d. capillaries,” Anal. Chem. 1992, 64, 3194. 20.Gale, D. C.; Smith, R. D. “Small volume and low flow-rate electrospray ionization mass spectrometry of aqueous samples,” Rapid Commun. Mass Spetrom. 1993, 7, 1017. 21.Wilm, S.; Mann, M. “Electrospray and taylor-cone theory dole’s beam of macromolecules at last ,” J. Mass Spectrom. Ion Processes. 1994, 136, 167. 22.Wilm, S.; Mann, M. “Analytical properties of the nanoelectrospray ion-source,” Anal. Chem. 1996, 68, 1. 23.Wang, C. S.; Shiea, J. “Applications of multiple-channel electrospray ionization sources for biological sample analysis, ” J. Mass Spectrom. 1997, 32, 247. 24.Lee, C. Y.; Shiea, J. “Gas chromatography connected to multiple -channel electrospray ionization mass spectrometry for the detection of volatile organic compounds,” Anal. Chem. 1998, 70, 2757. 25.Hong, C. M.; Tsai, F. C.; Shiea, J. “A multiple-channel electrospray source used to detect highly reactive ketenes from a flow pyrolyzer,” Anal. Chem. 2000, 72, 1175. 26.Hong, C. M.; Lee, C. T.; Lee, Y. M.; Kuo, C. P.; Yuan, C. H.; Shiea, J. “Generating electrospray from solution predeposited on a copper wire,” Rapid Commun. Mass Spectrom. 1999, 13, 21. 27.Kuo, C. P.; Shiea, J. “Application of direct electrospray probe to analyze biological compounds and to couple to solid-phase microextraction to dectect trace surfactants in aqueous solution,” Anal. Chem. 1999, 71, 4413. 28.Gomez, A.; Tang, K. “On the structure of an electrostatic spray of monodispers droplets, ” Phys. Fluid. 1994, 65, 404. 29.Dole, D.; Mack, L. L.; Hines, R. L.; Mobley, R. C.; Ferguson, L. D.; Alice, M. B. “Evidence of charge inversion in the reaction of single charged anions with multiply charged macroions,” Chem. Phys. 1968, 49, 2240. 30.Iribarne, J. V.; Thornson, B. A.; “On the evaporation of small ion from charged droplets,” J. Chem. Phys. 1976, 64, 15. 31.Rollgen, F. W.; Bramer-Wegner, E.; Butfering, L. “Field-ion emission from liquid solutions-ion evaporation against electrohydrodynamic disintegration,” J. Phys. 1987, 48, 253-256. 32.Loo, R. P. O.; Udseth, H. R.; Smith, R. D. “Evidence of charge inversion in the reaction of singly charged anions with multiply charged macroions, ” J. Phys. Chem. 1991, 95, 6412. 33.Loo, R. P. O.; Udseth, H. R.; Smith, R. D. “A new approach for the study of gas-phase ion-ion reactions using electrospray ionization,” J. Am. Soc. Mass Spectrom. 1992, 3, 695. 34. Loo, R. P. O.; Smith, R. D. “Investigation of gas-phase structure of electrosprayed proteins using ion-molecule reaction,” J. Am. Soc. Mass Spectrom. 1994, 5, 207. 35. Rulison, A. J.; Flagan, R. C. “Scale-up of electrospray atomization using linear arrays of taylor-cones,” Rev. Sci. Instrum. 1993, 64, 683. 36. Chang, D. Y.; Lee, C. C.; Shiea, J. “Detecting large biomolecules from high-salt solutions by fused-droplet electrospray ionization mass spectrometry,” Anal. Chem. 2002, 74, 2465. 37. Van Berkel, G. J.; McLuckey, S. A.;Glish, G. L. “Electrochemical origin of radical cations observed in electrospray ionization mass spectra,” Anal. Chem. 1992, 64, 1586. |
電子全文 Fulltext |
本電子全文僅授權使用者為學術研究之目的,進行個人非營利性質之檢索、閱讀、列印。請遵守中華民國著作權法之相關規定,切勿任意重製、散佈、改作、轉貼、播送,以免觸法。 論文使用權限 Thesis access permission:校內校外完全公開 unrestricted 開放時間 Available: 校內 Campus: 已公開 available 校外 Off-campus: 已公開 available |
紙本論文 Printed copies |
紙本論文的公開資訊在102學年度以後相對較為完整。如果需要查詢101學年度以前的紙本論文公開資訊,請聯繫圖資處紙本論文服務櫃台。如有不便之處敬請見諒。 開放時間 available 已公開 available |
QR Code |