獨立風能及柴油發電系統之動態及經濟分析 Dynamic Simulation and Economic Analysis of an Isolated Hybrid Wind Diesel System |
||
系所名稱 Department |
|||
畢業學年期 Year, semester |
語文別 Language |
||
學位類別 Degree |
頁數 Number of pages |
98 |
|
研究生 Author |
|||
指導教授 Advisor |
|||
召集委員 Convenor |
|||
口試委員 Advisory Committee |
|||
口試日期 Date of Exam |
2008-06-12 |
繳交日期 Date of Submission |
2008-06-24 |
關鍵字 Keywords |
none hybrid system, non-dispatchable, nature-dependent, economic analysis, MATLAB/Simulink |
||
統計 Statistics |
本論文已被瀏覽 5701 次,被下載 4224 次 The thesis/dissertation has been browsed 5701 times, has been downloaded 4224 times. |
中文摘要 |
none |
Abstract |
An isolated hybrid system comprised of a dispatchable and a non-dispatchable power generation sources, is proposed to supply the load of a remote village in the west region of Haiti. The wind speed data and load data of this remote village are used to study the system. The non-dispatchable generation comes from a nature-dependent wind turbine, and the dispatchable one is a diesel generator. Using MATLAB/Simulink, dynamic simulations are performed to investigate the interaction between these two power sources for the load management, and the voltage and frequency behaviors during wind speed and load variations. Economic analyses of the system are also conducted. The cost of energy (COE), energy payback time (PBT), internal rate of return (IRR) and avoided cost (AC) of CO2¬, NOx and PM (Particles Materials) of the hybrid system are computed, and results are compared with those of the baseline diesel only case. Simulation results show that the wind turbine and the diesel generator can be operated suitably in parallel, and the economic analyses show the positive benefits of wind generation in reducing COE and increasing the avoided cost (AC) of emitted pollutions. |
目次 Table of Contents |
Chapter 1 Introduction ………………………………………………………1 1.1 Background …………………….………………………………………………1 1.2 Literature Review..…………………………………………………………….4 1.3 Motivation for this work and thesis outline……..……………………………6 Chapter 2 Wind and Diesel Power Generation System…………………8 2.1 Wind Turbine Modeling………………………………………………………9 2.2 Self Excited Induction Generator (SEIG) Modeling…..……………………..13 2.2.1 Induction Machine..……………………………………………………….14 2.2.2 Equivalent electrical circuit of Induction Machine……………………15 2.2.3 Self Excited Induction Generator………………………………………15 2.3 Diesel Generation System…..………………………………………………..30 2.3.1 Diesel Engine Model.…..………………………………………………...31 2.3.2 Synchronous Generator Model and Equivalent Circuit……………...34 2.3.3 Parameters identification…………………………………………………38 Chapter 3 Hybrid Wind-Diesel Generation System……………………41 3.1 Hybrid wind/diesel system…………………………………………….42 3.2 System frequency control……………………………………………….42 3.3 Control principle…………………………………………………………45 Chapter 4 Economic Analysis of the Hybrid Wind/Diesel System…..56 4.1 Energy Demand… …………………………………………………….……..56 4.2 Diesel Energy System………………………………………………….………59 4.3 Wind Energy System…………………………………………………………...60 4.4 Wind-Diesel System…………………………………………….……………...61 4.5 Hybrid System Spreadsheet Model……………………………………………62 4.6 Costs Analysis…………………………………………………………………64 4.7 Wind-Diesel Hybrid System Economics………………………………………66 4.8 Sensitivity Analysis……………………………………………………………68 Chapter 5 Conclusion and Future Works.……………………………….71 5.1 Conclusion…….……………………………………………………………….71 5.2 Future works………………………………………………………………….. 72 References…………………………………………………………………………74 Appendix A Block diagram of the hybrid system in MATLAB/simulink for the simulations…………………………………………………………77 Appendix B System data for the economic analysis……………………………79 Appendix C Program used for the economic indices computation ………...…84 |
參考文獻 References |
[1] F. Schweppe, et al. “Homeostatic utility control,” IEEE Transactions on Power Apparatus and Systems, Volume PAS-99, No.3, May/June1980. [2] MATLAB/Simulink, SimPowerSystems Documentation Available: http://www.mathworks.com [3] M. F. Gillie and W. E. Leithead “Operation and regulation of a wind and gas virtual power plant,” 17th Intl. Conference Electricity Distribution, Barcelona, May 2003. [4] J. F. Manwell, J. G. Mc Govan and A. L. Rogers, Wind energy explained Theory, Design and Application, John Wiley& Sons, 2002, ch.7. [5] R. Hunter, and G. Elliot, (1994). Wind-Diesel Systems, Cambridge University Press. [6] M. R. Patel, Wind Power Systems, CRC Press, 1999, ch. 4-6. [7] G. L. Johnson, Wind Energy Systems, 2001. [8] A. D. Hansen, F. Iov, P. Sorensen, and F. Blaabjerg, “Overall control strategy of variable speed double-fed induction generator wind turbine,” Proceedings of Nordic Wind Power Conference, Chalmers University of Technology, Sweden 2004. [9] W. Q. Jeffries, J. G. Mc Gowan and J. F. Manwell, “Development of a dynamic model for no storage wind/diesel systems,” Wind Engineering, vol. 20, No. 1, 1996, pp 27-38. [10] J. G. Slootweg, “Wind power: modeling and impact on power system dynamics,” PhD dissertation, Dept. Elect. Eng., Delft University of Technology, Delft, Netherlands, 2003. [11] D. Seyoum, C. Grantham and M. F. Rahman, “The dynamic characteristics of an isolated self-excited induction generator driven by a wind turbine,” IEEE Trans. Industry Applications, vol. 39, no. 4, pp.936-944, July/August 2003. [12] M. H. Salama and P. G. Holmes, “Transient and steady-state load performance of stand alone self-excited induction generators,” Proceedings, IEE-Elect. Power Applications, vol. 143, no. 1, pp. 50-58, Jan. 1996. [13] S. S. Murphy, O. P. Malik and A. K. Tandon, “Analysis of self-excited induction generators,” Proceedings, IEE, pt. C, vol. 129, no. 6, pp. 260-265, Nov. 1992. [14] N. H. Malik and A. H. Al-Bahrani, “Influence of the terminal capacitor on the performance characteristics of a self-excited induction generators,” Proceedings, IEE, pt. C, vol. 137, no. 2, pp.168-173, Mar. 1990. [15] L. Quazene and G. Mcpherson Jr, “ Analysis of the isolated induction generator,” IEEE Trans. on Power Apparatus and Systems, vol. PAS-102, no. 8, pp. 2793-2798, Aug. 1983. [16] T. F. Chan, “Capacitance requirements of self-excited induction generators,” IEE Trans. Energy Conversion, vol. 8, no. 2, pp. 304-311, June 1993. [17] C. Grantham, D. Sutano and B. Mismail, “Steady-state and transient analysis of self-excited induction generators,” Proceedings, IEE, pt. B, vol 136, no. 2, pp. 61-68, March 1989. [18] C.M. Ong, Dynamic Simulation of Electric machinery, Printice Hall, 1998. [19] Paul C. Krause, O. Wasynczuk and S. D. Sudhoff, Analysis of Electric Machinery, IEEE Press, 2002. [20] F. Katiraei and M. R. Iravani, “Power management strategies for a microgrid with multiple distributed generation units,” Power Systems, IEEE Transactions on, pp. 1821 – 1831, Nov. 2006. [21] R. Gagnon, B. Saulnier, G. Sybille and P. Giroux, “Modeling of a generic high-performance of no storage wind-diesel system using MATLAB/Power systems block set,’’ European Wind Energy Association, Global Wind power conference (2002). [22] J. W. Black, M. Ilic, “Demand based frequency control for distributed generation, distributed power industry of the future,” IEEE 2002. |